News

2009-03-31: CANoe.ISO11783 5.1 SP1

Download

With Service Pack 1 (update to 5.1 build 25) the following changes become effective:

Trace window

  • More detailed interpretation of the messages VT12 and VT21 in the diagnostic column

Virtual Terminal

  • Learn mode for assignment of auxiliary functions to auxiliary inputs
  • Support of diagnostic information messages
  • Zoom mode available in case of multiple working sets now as well
  • Correct behavior in passive mode (no timeout)
  • Correct handling of Pointer Type 3 of Auxiliary Pointer Designator
  • Improved handling after modifying the settings

ISO11783 Node Layer

  • Object Pool API: supports assignment response for nodes supporting Virtual Terminal Version 2
  • Object Pool API: stores auxiliary assignments and sends preferred assignments
  • Object Pool API: supports learn mode for auxiliary assignments
  • Object Pool API: sends supported Virtual Terminal version in maintenance message if version > 2
  • Process Data API: sends correct Working-set task message

J1939 CAPL Generator

  • Support of Virtual Terminal Version 4

Features of Option .J1939

  • Correct display of J1939 string signals in Trace Window
  • J1939 Scanner: more information in online help for pages Nodes (description of the columns, e.g. First Change and Last Change) and Network(description of used arrows and display of inactive nodes)

 